The reflow soldering systems from SMT Wertheim stand for maximum efficiency and high product throughput with stable soldering quality. The parameterization of air flow with continuously adjustable fan units and a uniquely innovative heating zone concept enable a process-optimized soldering profile that can be flexibly applied to different products with constant temperature settings.

Technical Specifications

QP SQP MQP LQP L PlusQP XLQP XL Plus
External Dimensions
Length4672 mm5122 mm5754 mm6714 mm7169 mm7712mm
Width1435 mm1435 mm1435 mm1435 mm1435 mm1435 mm
Height (delivery condition/with warning light):1.)1767 / 2353 mm1767 / 2353 mm1767 / 2353 mm1767 / 2353 mm1767 / 2353 mm1767 / 2353 mm
Weight2.): approx.2300 kg2500 kg2900 kg3200 kg3400 kg3650 kg
Process Chamber
Pre-heat zones/peak zones / cooling zones:3 / 2 /23 / 2 / 24 / 2 / 35 / 3 / 35 / 3 / 36 / 4 / 3
Active convections length:2061 mm2511 mm3143 mm3630 mm4091 mm4628 mm
Active cooling length 3.):1057 mm1057 mm1531 mm1531 mm1531 mm1531 mm
Power
Power consumption steady state condition: 4.)appox. 7 kW happrox. 7 kW happrox. 9 kW happrox. 9 kW happrox. 11 kW h
· Standard height: 950 mm; corresponding to a changed inlet height
· Ø feet 80 mm, max. floor loading 750 kg/m²
· Up to 5 cooling zones possible. Each cooling zone: 474 mm
· Machine with chain conveyor, 220 mm transport width, fan speed reduction and no other options

Key Features

Highlights Reflow Systems

  • The heating zone concept enables process and energy efficiency to be maximized and guarantees the lowest energy and media consumption.
  • Reduced, tool-free maintenance effort and extension of maintenance intervals through optimized process gas cleaning directly in the process room. 
  • Stable cooling performance with continuously adjustable fan units with active monitoring and easy cleaning of the modular equipment within the cooling zone.
  • Exact nitrogen control through integrated lambda sensor technology and continuous real-time measurement of residual oxygen values. 
  • Process stability through monitoring software that detects the smallest deviations in the process gas flow.  
  • Fan units are gas-tight and maintenance-free for life.

Zone Concept

Fewer zones – fewer fan units – less consumption!

The number of zones has no influence on a good ΔT. The system is aligned according to the process and defined by the heating chamber length – not by the number of zones. A high air volume is important. SMT achieves this with few but powerful fans.

  •  Small ΔT with perfect heat transfer
  • 3 parts preheat (3 min) plus 1 part peak (1 min) corresponds to the 4 min IPC-JEDEC/solder paste recommendation

Process Gas Cleaning

  • Tool-free, easy maintenance from the front
  • lowest consumption of consumer goods
  • Process gas cleaning – ON THE SPOT
  • Cleaning directly in the process room
  • No extraction of process gases through piping necessary.

Cooling Concept

The cooling zone length and equipment (heat exchanger plates, optimized air baffles, etc.) can be flexibly selected. The cooling medium is supplied via an integrated cooling unit or an external cooling tower or the domestic water supply.

  • Stable cooling performance, no loss of performance over the operating time thanks to the use of smooth cooling plates
  • Cooling plates with long service lives and planned maintenance (cannot “clog up”), no replacement of the cooling plates necessary
  • Easy to clean

Intelligent Nitrogen Control

The intelligent nitrogen control with optimal control behavior reduces nitrogen consumption to a minimum. A nitrogen parameter that can be used for traceability is provided.

  • Lambda probe (automotive technology) in peak zone
  • Continuous live measurement of residual oxygen values
  • Probe replacement (calibration) in < 10 minutes

Process

Individual fan control in all zones

  • Individually adjustable fan speed in each zone (process optimization for flexible profile settings)
  • Increased energy saving potential
  • Active fan monitoring
  • Fan control is separate from the fan motors in the system (no thermal loads and therefore more durable)

System Models

Our Reflowsystems are individually adjustable.

R-Serie.

  • R460 – Heating Zone Length 4,6 m
  • R410 – Heating Zone Length 4,1 m
  • R360 – Heating Zone Length 3,6 m
  • R320 – Heating Zone Length 3,2 m

QP-Serie

  • Quattro Peak M – Heating Zone Length 2,6 m
  • Quattro Peak S – Heating Zone Length 2,1 m

Key Industries

  • Semiconductor, Solar & Electronics

Brand

Your download – just a few steps away

Please enter your details here:

test

Contact us