HF Scientific – Environmental Testing Equipment – AdvantEDGE Optical Dissolved Oxygen RDO® Electrode

  • SINGAPORE

    DKSH Singapore Pte Ltd
    625 Lorong 4 Toa Payoh, #03-00
    319519 Singapore
    Singapore

    +65 6471 1466

    Email

Measures dissolved oxygen (DO) in demanding environments

The AdvantEDGE Optical Dissolved Oxygen RDO® Electrode uses the latest technology to measure dissolved oxygen (DO) in demanding environments. The AdvantEDGE Series™ Optical Dissolved Oxygen RDO® sensor o­ffers several advantages for monitoring DO in process applications.

Technical Specifications

Sensor TypeLuminescent dissolved oxygen sensor
Transmitter/local displayOptional, not required
Range0 to 20 mg/L concentration0 to 200% saturation
Accuracy (DO)±0.1 mg/L, 0 to 8 mg/L±0.2 mg/L, 8 to 20 mg/L
Response time, capT90: 30 sec T95: 37 sec @ 25°C
Resolution0.01 mg/L
Usage life of cap1 year from the first instrument reading
Shelf life of cap2 years from date of manufacture(install within 1 year from date of manufacture)
Operating temperature0° to 50° (32° to 122°F)
IP ratingIP-67 with cap off, IP-68 with cap installed
ComplianceHeavy industrial, IEC 61000-6-2:2005
Storage conditions, cap1° to 60° (33° to 140°F), in factory container
Storage conditions, sensor-5° to 60° (23° to 140°F)
Salinity range0 to 42 PSU, fixed or real-time capable
pH range2-10 pH
Barometric range507-1115 mbar, fixed or real-time capable
Internal mounting thread1¼-11½ NPT
Communications optionsModbus RTU (RS485), 4-20mA, SDI-12
Maximum cable lengthUp to 4000 ft (Modbus and 4-20 mA)or up to 200 ft (SDI-12)
WarrantySensor: 3 years from date of manufactureCap: 2 years from date of manufacture

Key Features

  • Robust: Inert construction will not corrode in high salinity samples; Insensitive to common interferences such as hydrogen sulfide, chloride, chlorine, ammonium, and many others 
  • Cost effective options: Choose models for use with the economical LD500 Local Display; providing 4-20mA outputs and various communications protocols; Choose models available with integral 4-20 mA, Modbus RS-485, and SDI-12 outputs for direct connection to SCADA or PLC; totally eliminating the need for a separate transmitter/controller 
  • No calibration hassles: When used with the LD500 Local Display, no calibration is required; When connected directly to a SCADA or PLC, a one-time calibration is performed that lasts for 12 months 
  • Low maintenance: No electrolyte or membranes to replace; Sensor cap lasts 1 year without the need for recalibrations; Simply wipe the sensor cap periodically. Optional air blast accessory available 
  • Accurate: 0.1 mg/L accuracy from 0 – 8 mg/L DO, and 0.2 mg/L accuracy from 8 to 20 mg/L DO; Fast response to oxygen and temperature changes; Consistent, reproducible results (<0.05 mg/L reproducibility)

Key Industries

  • Aerospace
  • Agriculture
  • Automotive
  • Biopharmaceutical and Biotechnology
  • Chemical
  • Construction
  • Cosmetics & Personal Care
  • Defense
  • Die & Mould
  • Education & Academics
  • Electronics
  • Energy
  • Environmental
  • Food & Beverage
  • Luxury
  • Machinery & Manufacturing
  • Medical
  • Mining & Minerals
  • Oil & Gas
  • Optical
  • Paper & Wood
  • Pharmaceutical
  • Polymers, Plastics and Rubbers
  • Powders & Pigments / Coating
  • Railway
  • Semiconductor, Solar & Electronics
  • Service
  • Textile
  • Wholesale & Retail

Brand

HF Scientific

HF Scientific is a quality innovator of instrumentation focused on the measurement of cleanwater. They offer laboratory and on-line instruments to monitor important parameters in water and wastewater treatment plants.

Your download – just a few steps away

Please enter your details here:

test

Contact us